Background: Impairment of joint proprioception in patients with hypermobility syndrome (HMS) has been well documented. Both joint proprioception and muscle torque are commonly assessed in patients with musculoskeletal complaints. It is unknown, however, if these measures change significantly on repeated application in healthy children and in children with HMS.Aim: To investigate the between-days repeatability of joint proprioception and muscle torque in these groups.Methods: Twenty children (10 healthy and 10 with HMS), aged eight to 15 years, were assessed on two separate occasions (one week apart) for joint kinaesthesia (JK), joint position sense (JPS), and the extensor and knee flexor muscle torque of the knee. JK was measured using threshold to detection of passive movement. JPS was measured using the absolute angular error (AAE; the absolute difference between the target and perceived angles). Knee extensor and flexor muscle torque was normalized to body weight.Results: Intra-class correlation coefficients (ICC) for JK, extensor and flexor muscle torque were excellent in both groups (range 0.83 to 0.98). However, ICC values for JPS tests were poor to moderate in the two groups (range 0.18 to 0.56). 95% limits of agreement (LOA) were narrow in both cohorts for JK and muscle torque (indicating low systematic error) but wide for the JPS tests. 95% LOA also demonstrated that the measuring instruments used in this study had low between-days systematic error.Conclusions: Based on ICC and 95% LOA, the repeatability of JK and muscle torque measurements was excellent in both healthy children and those with HMS. The JPS test can only be assessed with poor to moderate repeatability. The use of the JPS test in these children should be undertaken with caution. Copyright © 2008 John Wiley & Sons, Ltd. (Source: Musculoskeletal Care)
Article/News Source:
Musculoskeletal Care
Repeatability of joint proprioception and muscle torque assessment in healthy children and in children diagnosed with hypermobility syndrome
Published in March 17th, 2008
Posted by Musculoskeletal Care in Uncategorized
No user responded in " Repeatability of joint proprioception and muscle torque assessment in healthy children and in children diagnosed with hypermobility syndrome "
Subscribes to this post comment rss or trackback urlSocial Network
Translators
Recent Entries
- Subject Index.
- Author Index.
- Emerging Technologies and Fourth Generation Issues in Cartilage Repair.
- Magnetic Resonance Imaging of Cartilage Repair.
- Cartilage Repair: Third-Generation Cell-based Technologies-Basic Science, Surgical Techniques, Clinical Outcomes.
- Second Generation Issues in Cartilage Repair.
- Minced Articular Cartilage-Basic Science, Surgical Technique, and Clinical Application.
- Cartilage Repair: Synthetics and Scaffolds: Basic Science, Surgical Techniques, and Clinical Outcomes.
- FDA Regulatory Pathways for Knee Cartilage Repair Products.
- Overview of Existing Cartilage Repair Technology.
Categories
-
- Arthroscopy (42)
- Chiropractic (20)
- Ergonomics (214)
- Manipulative Therapy (10)
- Manual Therapy (233)
- Massage Therapy (27)
- Musculoskeletal Disorders (70)
- Orthopaedics (431)
- Pediatric Physical Therapy (51)
- Physical Medicine (192)
- Physical Medicine and Rehabilitation (77)
- Physical Therapists (229)
- Physiotherapy (125)
- Products (108)
- Rehabilitation (319)
- Sports and Exercise (547)
- Sports Medicine (589)
- Uncategorized (333)
Archives
-
- November 2008
- October 2008
- September 2008
- August 2008
- July 2008
- June 2008
- May 2008
- April 2008
- March 2008
- February 2008
- January 2008
- December 2007
- November 2007
- October 2007
- September 2007
- August 2007
- July 2007
- June 2007
- May 2007
- April 2007
- March 2007
- January 2007
- December 2006
- November 2006
- September 2006
- August 2006
- June 2006
- May 2006