Background and Purpose. Understanding the reliability of selected measurement tools is a prerequisite to understanding the effects of clinical interventions. The aim of this investigation was to determine the reliability of the 50-Foot Timed Walk (50 FTW) and 30-second Chair Stand Test (30 CST) in subjects awaiting joint replacement surgery of the hip or knee. Methods. Eighty-two subjects participating in a 6-week exercise programme were assessed at baseline, 7 weeks and 15 weeks. Four trials of the 50 FTW and two trials of the 30 CST were completed at each assessment. Eleven trained assessors completed the assessments. Results. Intra-class correlations were consistently high for the 50 FTW and 30 CST at all assessments. At the baseline assessment, trial 1 was found to be significantly different from subsequent trials for both the 50 FTW and 30 CST. This effect was not evident at the 7-week and 15-week assessments. At the baseline assessment, scores for the 50 FTW became stable after the first trial. Estimates of minimum detectable change indicated that participants needed to change by more than 3.08 seconds and 1.64 stands to be 90% confident that a real change had occurred for the 50 FTW and 30 CST, respectively. Conclusion. The 50 FTW and 30 CST can be reliable measures of physical performance. However, because we found a practice effect at the baseline assessment, a practice trial should be allowed before data collection begins. Because only two trials of the 30 CST were completed, further research is required to confirm whether scores at the initial assessment become stable on repeated testing. Copyright © 2008 John Wiley & Sons, Ltd. (Source: Physiotherapy Research International)
Article/News Source:
Physiotherapy Research International
Reliability of performance-based measures in people awaiting joint replacement surgery of the hip or knee
Published in August 12th, 2008
Posted by Physiotherapy Research International in Physiotherapy
No user responded in " Reliability of performance-based measures in people awaiting joint replacement surgery of the hip or knee "
Subscribes to this post comment rss or trackback urlSocial Network
Translators
Recent Entries
- Subject Index.
- Author Index.
- Emerging Technologies and Fourth Generation Issues in Cartilage Repair.
- Magnetic Resonance Imaging of Cartilage Repair.
- Cartilage Repair: Third-Generation Cell-based Technologies-Basic Science, Surgical Techniques, Clinical Outcomes.
- Second Generation Issues in Cartilage Repair.
- Minced Articular Cartilage-Basic Science, Surgical Technique, and Clinical Application.
- Cartilage Repair: Synthetics and Scaffolds: Basic Science, Surgical Techniques, and Clinical Outcomes.
- FDA Regulatory Pathways for Knee Cartilage Repair Products.
- Overview of Existing Cartilage Repair Technology.
Categories
-
- Arthroscopy (42)
- Chiropractic (20)
- Ergonomics (214)
- Manipulative Therapy (10)
- Manual Therapy (233)
- Massage Therapy (27)
- Musculoskeletal Disorders (70)
- Orthopaedics (431)
- Pediatric Physical Therapy (51)
- Physical Medicine (192)
- Physical Medicine and Rehabilitation (77)
- Physical Therapists (229)
- Physiotherapy (125)
- Products (108)
- Rehabilitation (319)
- Sports and Exercise (546)
- Sports Medicine (588)
- Uncategorized (333)
Archives
-
- November 2008
- October 2008
- September 2008
- August 2008
- July 2008
- June 2008
- May 2008
- April 2008
- March 2008
- February 2008
- January 2008
- December 2007
- November 2007
- October 2007
- September 2007
- August 2007
- July 2007
- June 2007
- May 2007
- April 2007
- March 2007
- January 2007
- December 2006
- November 2006
- September 2006
- August 2006
- June 2006
- May 2006